Orgo-Life the new way to the future Advertising by AdpathwayA computational model observer achieved diagnostic concordance comparable to a clinical specialist when evaluating myocardial fluorine-18 fluorodeoxyglucose positron emission tomography scans for patterns indicative of active cardiac sarcoidosis, according to a retrospective diagnostic concordance study conducted by researchers at Tohoku University. In evaluating test datasets, the Channelized Hotelling Observer demonstrated an area under the receiver operating characteristic curve of 0.78 relative to an expert cardiac nuclear medicine physician standard, while an oncology nuclear medicine physician attained an area under the curve of 0.73. The investigation assessed whether algorithmic observers can provide an objective, mathematical alternative to subjective human visual assessments when classifying complex radiotracer uptake distributions.
Sarcoidosis represents an inflammatory granulomatous disorder of undetermined etiology, with cardiac sarcoidosis constituting the principal cause of mortality among afflicted individuals. Detection of active cardiac involvement routinely relies on cardiac positron emission tomography utilizing fluorine-18 labeled fluorodeoxyglucose, which identifies active inflammatory lesions through elevated myocardial tracer uptake. Clinical differentiation remains challenging because physiological radiotracer uptake frequently occurs within healthy myocardium as well as in other non-ischemic myocardial conditions such as dilated cardiomyopathy. Clinical image reading conventionally employs a visual schema dividing myocardial uptake into four discrete distributions: focal, focal on diffuse, diffuse, and none. The focal and focal on diffuse presentations are categorized as active cardiac sarcoidosis patterns, whereas diffuse and absent uptake are classified as negative findings.
Visual classification of these myocardial uptake configurations suffers from notable inter-observer variability, particularly along the continuum between diffuse physiological uptake and pathologic focal on diffuse patterns. While clinical guideline-directed diagnostic pathways incorporate multimodality inputs including electrocardiography and magnetic resonance imaging, assessing the isolated discriminatory capability of positron emission tomography scans presents methodological paradoxes when test images are pre-screened under established guideline criteria. To overcome human visual subjectivity and establish reproducible diagnostic metrics, the investigators implemented a Channelized Hotelling Observer, a signal-detection model that extracts spatial frequency representations from tomographic data to emulate observer decision-making processes.
The study cohort comprised 245 consecutive patients clinically suspected of having cardiac sarcoidosis who underwent cardiac positron emission tomography and computed tomography scanning between January 2015 and December 2019 at Tohoku University Hospital. Following the exclusion of 22 individuals due to age under 20 years or established coronary artery disease histories, the researchers examined imaging records from 223 final participants. Endomyocardial biopsy procedures had been performed in 126 of the 223 individuals, yielding definitive histological confirmation of cardiac sarcoidosis in 23 patients. Because definitive histological confirmation was limited across the retrospective sample, the researchers designed the trial to evaluate diagnostic concordance across observer platforms rather than absolute histological diagnostic accuracy.
Imaging protocols mandated that participants observe a dietary fast lasting at least 12 hours prior to tracer administration to suppress baseline physiological glucose utilization within normal myocytes. Patients received intravenous administration of approximately 3.7 megabecquerels of fluorine-18 fluorodeoxyglucose per kilogram of body weight, with a capped dosage of 333 megabecquerels administered to individuals weighing over 90 kilograms. Following an uptake period of approximately one hour, scanning commenced on a Biograph-40 scanner utilizing spiral computed tomography for attenuation correction. Emission data were obtained from the chest through the upper abdomen, with 139 patients scanned over three thoracic bed positions for five minutes per position and reconstructed into 256 by 256 matrices. An additional 84 patients underwent whole-body acquisitions across eight bed positions at two minutes per bed position, reconstructed into 168 by 168 matrices and subsequently resampled to match thoracic dimensions.
Two independent specialists evaluated the 223 examinations using commercial image display software after completing a standardized one-hour preliminary training session. The reference standard observer was an expert cardiac nuclear medicine physician possessing 26 years of specialized clinical experience, while the comparative human reader was an oncology nuclear medicine physician with 20 years of clinical experience. Both specialists independently assigned each scan to one of the four uptake patterns without conferring. In addition to categorical pattern assignments, the oncology nuclear medicine physician recorded a subjective continuous confidence rating for active cardiac sarcoidosis likelihood ranging from 0 to 100 percent for each examination.
Independent categorizations by the two physicians yielded a moderate level of concordance, reflected by an overall Cohen kappa coefficient of 0.57. Categorical agreement ratios between the cardiac and oncology specialists across specific uptake classifications were 23 of 31 for focal uptake, 33 of 75 for focal on diffuse uptake, 50 of 68 for diffuse uptake, and 46 of 49 for absent uptake. Across the entire cohort, 84 patients received conflicting pattern categorizations between the two readers, with approximately 50 percent of all discordant interpretations involving cases where one reader identified a focal on diffuse pattern while the alternative reader chose a differing category. Disagreements occurred predominantly in the basilar ventricular septum and the posterolateral myocardial wall.
The mathematical observer framework processed volumetric positron emission tomography datasets resliced along cardiac short, horizontal long, and vertical long axes following manual identification of the left ventricular apex and cardiac orientation angles. The Channelized Hotelling Observer transformed masked transverse image slices into spatial frequency representations via two-dimensional Fourier transformation. Radially symmetric bandpass filters divided the frequency domain into five concentric channels utilizing an initial cutoff frequency of 0.03125 cycles per pixel. Channelized feature vectors were integrated across slices and multiplied by pre-whitening matched filter weights derived from the inverse covariance matrices of training cohorts to compute scalar decision test statistics.
To train and validate the computational pipeline, the 223 subjects were randomly partitioned into a balanced training cohort of 80 subjects containing 40 positive and 40 negative cases based on the cardiac specialist reference classifications, alongside an independent evaluation cohort of 143 subjects consisting of 66 positive and 77 negative cases. The continuous test statistic generated by the model observer was normalized to a 0-to-100 scale to permit direct receiver operating characteristic curve comparisons against the continuous ratings generated by the oncology physician. The investigators further evaluated three distinct volume of interest masking geometries on the left ventricle: a 7.0-centimeter radius sphere, a 5.6-centimeter radius sphere, and a closely fitted orbital elliptical shell enclosing the left ventricular myocardium.
Receiver operating characteristic curve analysis revealed that the diagnostic discrimination of the Channelized Hotelling Observer varied according to the specific volume of interest selected for pixel normalization. Without normalization, the model observer produced an area under the curve of 0.70, which increased across localized normalization schemes to reach values between 0.74 and 0.78. Normalization anchored to the closest elliptical shell matching myocardial contours generated the peak area under the curve of 0.78, outperforming spherical regions of interest by isolating maximum myocardial pixel intensity values while eliminating surrounding extracardiac uptake. The oncology specialist demonstrated an area under the curve of 0.73 when judged against the reference standard, showing statistical equivalence to the computational model observer.
The investigators emphasized several methodological parameters that temper clinical generalization. The investigation utilized diagnostic assignments from a single experienced cardiac nuclear medicine physician as the comparative reference standard rather than consensus panel judgments or biopsy validation, which introduces potential single-reader classification biases. Additionally, spatial preprocessing of whole-body scans involved trilinear interpolation resampling to match dedicated thoracic reconstructions, and all volumes of interest were configured by a single operator, preventing assessment of inter-operator variation. Furthermore, while patients fasted for at least 12 hours, variable suppression of physiological myocardial glucose uptake may have influenced diffuse and absent background patterns, underscoring the need for larger prospective cohorts with definitive histological verification.
Subject of Research: Evaluation of a Channelized Hotelling Observer for detecting active cardiac sarcoidosis patterns on 18F-FDG PET imaging
Article Title: Detection ability of model observer for diagnosis of active cardiac sarcoidosis on 18F-FDG-PET
Article References: Naoi, J., Takanami, K., Kiso, K., Shidahara, M., Odagiri, H., Sakai, D., Noda, T., Yasuda, S., & Takase, K. (2026). Detection ability of model observer for diagnosis of active cardiac sarcoidosis on 18F-FDG-PET. Annals of Nuclear Medicine, 40(11), 1311-1318. https://doi.org/10.1007/s12149-026-02248-3
Image Credits: AI Generated
DOI: 10.1007/s12149-026-02248-3
Keywords: Cardiac Sarcoidosis, 18F-FDG PET, Positron Emission Tomography, Channelized Hotelling Observer, Model Observer, Nuclear Medicine, Myocardial Uptake, Receiver Operating Characteristic, Area Under the Curve, Image Interpretation, Kappa Coefficient, Medical Image Processing, Fourier Transform, Volume of Interest, Tohoku University Hospital, Biograph-40


5 hours ago
12




















English (US) ·
French (CA) ·