Formaldehyde Injection During Biopsy Causes Oral Mucosa Necrosis

3 hours ago 8

PROTECT YOUR DNA WITH QUANTUM TECHNOLOGY

Orgo-Life the new way to the future

  Advertising by Adpathway

A 60-year-old woman experienced severe oral mucosa necrosis following an accidental injection of formaldehyde into her lower lip during a minor salivary gland biopsy. The incident, reported in the journal Patient Safety in Surgery, highlights a rare but preventable iatrogenic complication arising from the mishandling of medical substances. The case illustrates how a simple procedural error, specifically the confusion between a local anesthetic and a chemical fixative, can lead to significant tissue damage and the need for extensive surgical intervention.

The patient initially presented with a history of dry mouth that had persisted for approximately one year. As part of the etiological work-up for this condition, her primary care physician performed a biopsy of the minor salivary glands. The procedure was conducted under local anesthesia, utilizing 2% lidocaine, with the tissue sample taken from the inner aspect of the lower lip.

Shortly after the anesthetic was injected, the patient reported severe, unbearable pain described as a burning sensation at the injection site. This immediate reaction prompted the physician to halt the procedure and verify the contents of the vial being used. It was then revealed that the assistant had been using empty lidocaine vials to store formaldehyde for the purpose of preserving biopsy specimens. This practice led to the inadvertent injection of formaldehyde, a highly reactive substance, directly into the patient’s oral mucosa.

Formaldehyde is widely used in medical practice as a fixative due to its ability to bind instantly to electron-rich biomolecules, including structural proteins and nucleic acids. This rapid chemical interaction triggers profound cellular damage and alters tissue homeostasis, ultimately causing widespread necrosis and localized tissue death. The introduction of formaldehyde into the human body can result in significant damage to the skin, mucosa, gastrointestinal tract, and respiratory system, with potential for life-threatening systemic complications.

In the days following the procedure, the patient’s condition deteriorated. She was initially managed with oral antibiotics and analgesics and was asked to attend daily consultations for monitoring. However, the next day she presented with labiomental erythema, persistent pain, and a sensation of firm skin on palpation. Intraoral examination revealed a necrotic mucosal area covered by a whitish coating at the injection site, measuring approximately 5 cm in its greatest dimension.

Due to the unfavorable progression of symptoms, the patient was admitted to the hospital for further management. Laboratory tests performed upon admission returned normal results. She was started on intravenous antibiotic therapy, specifically amoxicillin combined with clavulanic acid at a dose of 1 g every 8 hours. The development of labiomental cellulitis necessitated this escalation in care, as the initial oral treatment proved insufficient to control the spreading infection and tissue damage.

Two days after hospitalization, following clear delineation of the necrotic area, the patient underwent surgical necrosectomy and thorough debridement in the operating room. The resulting tissue defect was repaired using local flap mobilization and resorbable sutures. Postoperative care included the application of a pro-healing ointment intraorally and the use of bicarbonate mouth rinses to support the healing process and maintain oral hygiene.

The patient’s hospitalization lasted seven days, during which she received daily monitoring. Her recovery was marked by the resolution of erythema and pain, with very satisfactory intraoral healing observed fifteen days after the necrosectomy. The successful outcome underscores the importance of timely and aggressive surgical intervention in cases of chemical-induced tissue necrosis, particularly when secondary infections such as cellulitis develop.

This case is not unique in the medical literature, though it remains rare. A similar incident was reported by Kerure et al., where a patient received an accidental injection of formaldehyde intended as local anesthesia before the removal of a sebaceous cyst. Another comparable diagnostic error was reported by Kamaleddine et al., involving the inadvertent injection of formaldehyde during a prostate biopsy, which led to rapid protein coagulation, extensive rectal wall necrosis, and subsequent perforation. These cases collectively highlight the potential for severe iatrogenic harm when chemical handling protocols are not strictly followed.

The management of such cases in the literature generally involves early administration of broad-spectrum antibiotics, surgical debridement of necrotic tissue, and close daily monitoring. In the case described by Bector et al., an intraoral injection of formaldehyde led to facial cellulitis, requiring similar aggressive management.

The primary purpose of this report is to draw attention to the practices involved in handling medical substances, particularly the identification of containers holding potentially harmful or caustic agents. The incident occurred because the assistant stored biopsy specimens in empty lidocaine vials filled with formaldehyde, leading to formaldehyde being mistaken for lidocaine. This highlights the critical need for effective verification procedures to prevent such incidents in clinical settings.

To prevent this severe complication from occurring in the future, the authors recommend that healthcare facilities implement an absolute ban on the reuse of empty anesthetic vials for specimen fixation. Additionally, the mandate for the use of color-coded, pre-labeled containers for chemicals is proposed to ensure clear identification of contents. Enforcing a double-check verification protocol prior to any local anesthetic administration is also recommended to provide an additional layer of safety against such errors.

The case serves as a stark reminder that even in routine procedures, the handling of medical substances requires foolproof institutional safeguards. The rapid onset of symptoms and the severity of the tissue damage demonstrate the high reactivity of formaldehyde and its potential to cause extensive harm when introduced into the body.

This report contributes to the growing body of evidence on patient safety in surgical and diagnostic procedures, emphasizing the importance of vigilance and standardized practices in preventing iatrogenic complications. By sharing this case, the authors aim to raise awareness among clinicians and healthcare institutions about the risks associated with improper chemical storage and the necessity of robust verification systems in clinical practice.

Subject of Research: Case report on oral mucosa necrosis resulting from accidental formaldehyde injection during a minor salivary gland biopsy.

Article Title: Oral mucosa necrosis after accidental formaldehyde injection during salivary gland biopsy: case report of a rare preventable complication

Article References: Bouanani, O. (2026). Oral mucosa necrosis after accidental formaldehyde injection during salivary gland biopsy: case report of a rare preventable complication. Patient Safety in Surgery, 20(1), Article 33. https://doi.org/10.1186/s13037-026-00496-w

Image Credits: AI Generated

DOI: 10.1186/s13037-026-00496-w

Keywords: oral mucosa necrosis, formaldehyde injection, salivary gland biopsy, iatrogenic complication, medical safety, tissue necrosis, surgical necrosectomy, labiomental cellulitis, chemical mishandling, patient safety, local anesthetic error, oral surgery, formaldehyde fixative, clinical protocol, tissue repair, medical error, oral pathology, surgical debridement, case report, infection management

Read Entire Article

         

        